The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements

Hua, Xijin, Li, Junyan ORCID logoORCID: https://orcid.org/0000-0003-4053-8334, Wang, Ling, Wilcox, Ruth, Fisher, John and Jin, Zhongmin (2015) The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements. Medical Engineering and Physics, 37 (10) . pp. 1008-1014. ISSN 1350-4533 [Article] (doi:10.1016/j.medengphy.2015.08.003)

[img]
Preview
PDF - Final accepted version (with author's formatting)
Available under License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0.

Download (313kB) | Preview

Abstract

One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs.

Item Type: Article
Research Areas: A. > School of Science and Technology > Natural Sciences > Biophysics and Bioengineering group
Item ID: 21900
Notes on copyright: © 2015. This author accepted manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
Useful Links:
Depositing User: Junyan Li
Date Deposited: 05 Jun 2017 15:34
Last Modified: 29 Nov 2022 22:25
URI: https://eprints.mdx.ac.uk/id/eprint/21900

Actions (login required)

View Item View Item

Statistics

Activity Overview
6 month trend
252Downloads
6 month trend
328Hits

Additional statistics are available via IRStats2.